MODEL: T106R
LR3730
24 HOUR DIAL TIME SWITCH IN TYPE 3R RAINPROOF ENCLOSURE SUITABLE FOR POOL
EQUIPMENT CONTROL IF INSTALLED 5 FT. [. . . ] To wire as SINGLE POLE NORMALLY CLOSED, move motor lead from terminal 3 to 1, and connect LINE to 1, LOAD to 2. To wire as SINGLE POLE DOUBLE THROW, install jumper (the same gauge as LINE wire) between terminals 2 and 3 and connect LINE to 2, LOADS to 1 and 4. REPLACE INSULATOR BEFORE TURNING ON ELECTRICITY.
MINIMUM COPPER WIRE SIZE (AWG) MAX. 240 V.
PRESSURE PLATE TERMINAL SCREW MAKE SURE WIRE INSULATION CLEARS PRESSURE PLATE
14 12 10 8
15 20 30 40
60 60 60 75
1/2 1 2 -
2 2 1/2 3 5
N/A
N/A
PROGRAMMING INSTRUCTIONS 1. TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. Turn in either direction and align the exact time-of-day on the CLOCKDIAL (the time now, when switch is being put into operation) to the pointer. [. . . ] See programming instructions.
INTERMATIC INCORPORATED